KS02 • 16-SECTION CONCEPT PROJECT ANALYSIS • 500 M²

KS02 — 500 m² Cold Storage Building Concept Project & 16-Section Engineering Analysis

KS02 (25.0 m × 20.0 m × 5.5 m) cold storage building concept: structural steel, insulated panel schedule, door package, and 16-section engineering analysis.

500 m² 25.0 m × 20.0 m × 5.5 m
EN 1090 EXC2 Bolted Steel Structure
B-s1,d0 PIR 100–200 mm Cold Envelope
5 Kademe Flexible Supply Tiers
KS02 — 500 m² Cold Storage Building Concept Project & 16-Section Engineering Analysis — SerPan Cold
KS02 (500 m²): 25.0 m × 20.0 m × 5.5 m

Fiche Récapitulative Technique

KS02
Concept Code & Footprint
KS02 500 m² (25.0 m × 20.0 m × 5.5 m)
Structural System
Çelik Karkaslı Bağımsız Depo Binası veya Büyük Fabrika İçi Kurulum
Chamber & Zoning Summary
2 Adet 0/+4°C Soğuk Muhafaza (220 m²) + 1 Adet -20°C Donmuş Muhafaza (130 m²) + +8/+12°C Ön Koridor / Sas (100 m²) + İdari/Teknik 50 m²
Door Schedule Summary
3 Adet 1400×2200 mm Sürgülü Soğuk Oda Kapısı (D02) + 2 Adet Yalıtımlı Rampa Kapısı (D07) + 2 Adet Servis Kapısı
Panel & Envelope Schedule
100 mm ve 150 mm Sürekli Hat PIR/PUR Soğuk Oda Panelleri + T-Askı Sistemi ~1.420 m²
Refrigeration & Controls
3 Adet Yarı Hermetik Split Grup veya Kompakt Merkezi Sistem + Uzaktan İzleme (R04)
Endüstriyel Kapı ve Soğutma Paketi — SerPan Cold KS02 • KAPI & SOĞUTMA

Industrial Door Package & Refrigeration Units

3 Adet 1400×2200 mm Sürgülü Soğuk Oda Kapısı (D02) + 2 Adet Yalıtımlı Rampa Kapısı (D07) + 2 Adet Servis Kapısı — 3 Adet Yarı Hermetik Split Grup veya Kompakt Merkezi Sistem + Uzaktan İzleme (R04)

BÖLÜM 02

2. Executive Overview & Target Investor Profile

KS02 (500 m²) — Bölgesel Gıda Dağıtıcıları, Meyve-Sebze Paketleme, Süt/Peynir Tesisleri ve İhracat Depoları

BÖLÜM 03

3. Architectural Dimensions & Zoning Principle

25.0 m × 20.0 m × 5.5 m — 2 Adet 0/+4°C Soğuk Muhafaza (220 m²) + 1 Adet -20°C Donmuş Muhafaza (130 m²) + +8/+12°C Ön Koridor / Sas (100 m²) + İdari/Teknik (50 m²)

4. Detailed Space Program Breakdown

Functional Zone Approx. Area (m²) Target Temperature Regime Engineering Role
Chilled & Frozen Storage Chambers 340 m² +2/+4°C & -18/-22°C Primary palletized/crated cold storage volume
Conditioned Ante-Room & Staging Corridor (Sas) 80 m² +8°C / +12°C Thermal airlock preventing warm ambient air ingress during order picking
Loading Dock & Buffer Zone 50 m² +10°C / +15°C Truck docking interface with sectional doors and dock shelters
Plant Room & Dispatch Office 30 m² +18°C / +22°C Refrigeration racks/units, electrical panels, and logistics office
BÖLÜM 05

5. Structural Steel Engineering (SerHangar)

Çelik Karkaslı Bağımsız Depo Binası veya Büyük Fabrika İçi Kurulum (~22 tonnes SerHangar bolted structural steel).

BÖLÜM 06

6. External Roof & Facade Cladding System (SerPan Metal)

3-Rib / 5-Rib PUR/PIR Roof Sandwich Panels (P13) + Secret-Fix / Standard Facade Sandwich Panels (P14).

BÖLÜM 07

7. Internal Cold Envelope, Ceiling T-Suspension & Floor Insulation

100 mm ve 150 mm Sürekli Hat PIR/PUR Soğuk Oda Panelleri + T-Askı Sistemi (~1.420 m²) + T-Bar Ceiling Suspension (A05) + High-Compressive Floor Insulation (P12).

BÖLÜM 08

8. Door Schedule & Traffic Flow

3 Adet 1400×2200 mm Sürgülü Soğuk Oda Kapısı (D02) + 2 Adet Yalıtımlı Rampa Kapısı (D07) + 2 Adet Servis Kapısı + Steel Protection Bollards (A07).

BÖLÜM 09

9. Hygienic Cove Skirtings & Food Safety (HACCP)

HACCP / BRCGS / IFS R45 Antibacterial PVC Rounded Cove Skirtings & Corner Profiles (A02 / SPC-SO-HP).

BÖLÜM 10

10. Industrial Refrigeration, Evaporators & Automation

3 Adet Yarı Hermetik Split Grup veya Kompakt Merkezi Sistem + Uzaktan İzleme (R04)

BÖLÜM 11

11. Energy Efficiency, Vapor Barrier & Thermal-Break Detailing

Continuous thermal-break corner cuts, PU foam joint injection, and Heated Pressure Relief Valves (A03).

BÖLÜM 12

12. Investment & 5-Tier Supply Options

Available as Pre-Engineered Building Kit (B02), Installed Thermal Shell, or Full Turnkey Facility (B04).

BÖLÜM 13

13. Work Package & Responsibility Matrix (EK H05)

Scope boundaries are defined transparently in DOC16 (EK H05 Scope Responsibility Matrix).

DOC16 — EK H05 Matrisi
BÖLÜM 14

14. Dispatch, Export Kit & Site Erection Workflow

Numbered shop drawings and export container/mega-truck loading optimization from Gebze / Kocaeli.

CAD SCHEMATIC 04 — FACILITY FLOW PLAN

Sample Cold Storage Facility Layout (Ante-Room Corridor + Multi-Chamber + Docks)

For energy efficiency and cold-chain integrity, all chilled and frozen chambers open into a conditioned (+8/+12°C) staging corridor rather than directly outdoors.

CHAMBER 01: FREEZER (-20°C) 150 mm PIR Panel + Sliding Door CHAMBER 02: CHILLER (+2°C) 100 mm PIR Panel + Sliding Door BLAST (-38°C) 200 mm Panel PLANT ROOM & OFFICE +8°C / +12°C CONDITIONED ANTE-ROOM CORRIDOR (SAS) — BOLLARD PROTECTED Sectional Dock Doors (D07) ↓          Dock Shelters ↓
BASE DE CONNAISSANCES TECHNIQUES (EK C)

Questions Fréquentes sur l'Ingénierie et la Fourniture

Questions techniques fréquentes sur les portes frigorifiques, le choix de l’épaisseur des panneaux, l’étanchéité et les projets clé en main.

C31 What is the difference between building cold rooms inside an existing factory ("Box-in-Box") vs constructing a standalone cold storage building?

In a "Box-in-Box" project, the outer building already exists and insulated rooms are built inside. In a standalone "Cold Storage Building", SerPan Cold + SerHangar engineer the structural steel frame, external roof/facade cladding, internal insulated envelope, and loading docks as a single integrated facility.

C32 How are thermal bridges prevented in steel-framed cold storage buildings?

Primary steel columns and rafters are positioned outside the insulated thermal envelope wherever possible, with ceiling panels suspended via thermal-break hangers. Any internal columns are fully boxed with insulated panels and PU-injected joints.

C33 What is included in a Cold Storage Building Kit (B02)?

A pre-engineered package comprising structural steel members, external roof/facade cladding, internal cold room wall/ceiling panels, all insulated and traffic doors, flashing/corner profiles, suspension hardware, and assembly drawings—ideal for export and remote sites.

C34 Who handles civil works and concrete floor slabs in turnkey cold storage projects?

Foundations and civil concrete works are typically executed by the client's local civil contractor according to SerPan Cold load and elevation drawings, while floor vapor barriers, insulation, structural steel, panels, doors, and refrigeration are clearly defined in our Scope Matrix (EK H05).

C35 Why is the loading dock and sectional door interface critical for cold storage performance?

The truck dock interface is the most vulnerable link in the cold chain. Integrating insulated dock doors, inflatable/curtain dock shelters, and a conditioned staging corridor prevents ambient air infiltration during loading.

BUREAU D’INGÉNIERIE & DEVIS DIRECT

Sélectionnez Votre Parcours de Devis (4 Voies Techniques)

Sélectionnez le parcours adapté à votre besoin ; vos dimensions et paramètres seront transmis directement à notre bureau d’études sur WhatsApp. (+90 (505) 507 04 18)

BUREAU D’ÉTUDES SERPAN COLD

Obtenez un Devis Rapide pour Portes Frigorifiques, Panneaux ou Bâtiments Frigorifiques

Qu’il s’agisse d’une porte sur mesure, d’un lot de panneaux ou d’un entrepôt frigorifique clé en main, transmettez vos dimensions pour un chiffrage détaillé.

Fabrication Sur Mesure 60–200 mm PUR/PIR Charpente Acier SerHangar Export vers 32+ Pays
Ligne Ingénierie WhatsApp