200 MM PUR / PIR • U = 0.11 W/m²K

200 mm PUR / PIR Cold Room Panel: U-Value, Temperature Regime & Specifications

200 mm PUR/PIR cold room wall and ceiling panel (0.11 W/m²K) engineered for -35°C / -40°C Endüstriyel Şoklama Tüneli with maximum span and compatible door selection.

200 mm 42 kg/m³ PUR / PIR
0.11 W/m²K Thermal U-Value
-35°C / -40°C Endüstriyel Şoklama Tüneli Operating Regime
6.50 m Max Ceiling Span
200 mm PUR / PIR Cold Room Panel: U-Value, Temperature Regime & Specifications — SerPan Cold
PNL-200: 200 mm PUR/PIR (0.11 W/m²K)

Ficha Técnica Resumida

200 MM PUR / PIR PANEL
Panel Thickness & Density
200 mm PUR / PIR Panel 40–42 kg/m³ Yoğunluk • EN 14509 & B-s1,d0
Thermal Transmittance (U-Value)
U = 0.11 W/m²K Recommended Temperature Regime: -35°C / -40°C Endüstriyel Şoklama Tüneli
Max Self-Supporting Ceiling Span
6.50 m Serbest Açıklık Ağırlık: 16.8 kg/m² • 0.50 mm Çift Yüz Sac
Compatible Cold Room Door
200 mm Çift Rezistanslı Ağır Hizmet Şok Kapısı + Çift Basınç Denge Valfi Gebze Fabrika Çıkışlı Özel Boy & Eksantrik Kilitli Üretim

Where Is the 200 mm Cold Room Panel Used?

With a thermal transmittance of 0.11 W/m²K, the 200 mm PUR/PIR cold room panel eliminates exterior surface condensation and minimizes compressor run-time in chambers operating at -35°C / -40°C Endüstriyel Şoklama Tüneli.

When ceiling spans exceed 6.50 m, panels are suspended from overhead steel purlins using our thermal-break aluminum T-bar suspension system (A05).

Explore Other Panel Thicknesses (60 mm – 200 mm)

CAD SCHEMATIC 05 — PANEL JOINT & HYGIENIC COVE DETAIL

Deep Labyrinth / Cam-Lock Panel Joint & HACCP Rounded Cove Section

Thermal-break tongue-and-groove polyurethane joint geometry combined with R45 rounded PVC hygienic skirting that eliminates 90° bacterial traps.

1. LABYRINTH JOINT & CAM-LOCK DETAIL Cam-Lock + Dual Gasket Groove (40–42 kg/m³ PIR/PUR) 2. HACCP ROUNDED HYGIENIC COVE SKIRTING (A02) R45 Rounded PVC Cove Flexible Co-Extruded Lip Eliminates 90° Bacterial Traps
BASE DE CONOCIMIENTO TÉCNICO (EK C)

Preguntas Frecuentes de Ingeniería y Suministro

Preguntas técnicas frecuentes sobre puertas frigoríficas, selección de espesor de panel, sellado térmico y proyectos llave en mano.

C11 Which cold room panel thickness should be selected for each operating temperature regime?

General engineering guideline: 60–80 mm for +8/+15°C cool storage, 80–100 mm for +2/+8°C chillers, 100 mm for 0/+4°C fresh storage, 120–150 mm for -18/-22°C freezers, 150–180 mm for -25/-30°C deep freeze, and 180–200 mm for -35/-40°C blast freezers.

C12 What is the main difference between PUR and PIR insulated cold room panels?

Both provide high thermal insulation at 40–42 kg/m³ density, while PIR (Polyisocyanurate) features an enhanced isocyanurate ring structure that delivers superior fire resistance, reduced smoke emission, and compliance with industrial property insurance standards.

C13 What is the difference between Cam-Lock modular panels and continuous-line slip-joint panels?

Cam-lock modular panels allow rapid assembly and future disassembly/relocation for walk-in cold rooms. Continuous-line labyrinth slip-joint panels are engineered for tall industrial cold storage buildings and long partition walls up to 13.5 meters.

C14 Why is floor insulation critical in cold rooms and freezer chambers?

Without proper floor insulation in sub-zero rooms, ground moisture freezes and expands (frost heave), cracking the concrete slab. Modular rooms use birch-plywood + stainless steel floor panels, while forklift-rated warehouses use multi-layer high-compressive XPS/PIR below a reinforced concrete slab with underfloor heating or ventilation.

C15 Why are hygienic cove skirtings and rounded internal/external corner profiles (A02) required?

Sharp 90-degree wall-to-floor and wall-to-wall angles trap bacteria and organic residues. HACCP, IFS, and BRCGS food safety audits require coved (rounded radius) PVC/aluminium hygienic profiles for effortless sanitation.

C16 Which cold rooms require a pressure relief valve (A03)?

Rapid air contraction after door closure or defrost cycles creates strong vacuum pressure inside sealed rooms. Heated pressure relief valves are mandatory in all sub-zero freezers and blast rooms to prevent panel implosion and vacuum-locked doors.

MESA DIRECTA DE INGENIERÍA Y OFERTAS

Seleccione su Vía de Presupuesto (4 Canales Técnicos)

Seleccione el flujo adecuado a su proyecto; sus medidas y criterios técnicos se enviarán directamente a nuestra Mesa de Ingeniería por WhatsApp. (+90 (505) 507 04 18)

MESA DE INGENIERÍA SERPAN COLD

Solicite Cotización Rápida para Puertas Frigoríficas, Paneles o Naves de Frío

Ya sea un pedido de puertas/paneles o una nave frigorífica llave en mano, envíenos sus medidas para recibir una oferta técnica desglosada en el mismo día.

Fabricación a Medida 60–200 mm PUR/PIR Estructura de Acero SerHangar Exportación a 32+ Países
Línea de Ingeniería WhatsApp