STEEL-FRAMED COLD STORAGE SISTEMAS DE INGENIERÍA SERPAN COLD

Steel-Framed Cold Storage Warehouse Buildings

A cold storage steel structure differs fundamentally from a standard warehouse frame: it must be statically engineered for suspended insulated ceilings, heavy multi-fan evaporators, meat monorail loads, and thermal-break envelopes.

+15°C → -40°C Chiller, Freezer & Blast Regimes
60 – 200 mm 40–42 kg/m³ PUR & PIR Core
EN 10346 & HACCP 9-Layer Hygienic Steel & Profiles
81 İl & 32+ Ülke Direct Dispatch from Gebze Hub
Steel-Framed Cold Storage Warehouse Buildings — SerPan Cold
STEEL-FRAMED COLD STORAGE: Steel-Framed Cold Storage Warehouse Buildings

Ficha Técnica Resumida

STEEL-FRAMED COLD STORAGE
Taşıyıcı Karkas
Cıvatalı Ağır & Hafif Çelik Sistem SerHangar Mühendisliği İle Deprem ve Kar Yüküne Göre Statik Proje
Açıklık & Yükseklik
12–35 m Açıklık • 5.0–12.5 m Yükseklik Kolonsuz Geniş Depolama Holleri ve Yüksek Palet Raf Uyumu
Isı Köprüsü Kontrolü
Dıştan Karkas + T-Askı Tavan Zarfı Çelik Kirişlerin Soğuk Odaya Girmesini Önleyen Kesintisiz Zarf
Fabrika Ön Üretimi
%100 Cıvatalı & Boyalı Sevkiyat Şantiyede Kaynak Gerektirmeyen Hızlı ve Temiz Montaj Süreci

Matriz de 5 Paquetes Comerciales y Alcance Llave en Mano (EK H05)

Definimos con total transparencia qué paquetes ejecuta SerPan Cold y cuáles quedan en el alcance civil/mecánico local:

PAKET 01

Solo Suministro de Producto (Puertas / Paneles / Accesorios)

Cliente Objetivo: Instaladores frigoristas, contratistas mecánicos, distribuidores y plantas con equipo propio.

Alcance Incluido: Puertas frigoríficas a medida, paneles aislantes, perfiles sanitarios, herrajes y embalaje de exportación.

PAKET 02

Envolvente Aislante (Paneles + Puertas + Montaje en Obra)

Cliente Objetivo: Inversores que adquieren el equipo frigorífico por separado pero desean el montaje garantizado de paneles y puertas.

Alcance Incluido: Paneles de pared, techo y suelo, puertas frigoríficas, suspensión en T, perfiles sanitarios y montaje completo en obra.

PAKET 03

Cámara Frigorífica Completa (Envolvente + Equipo de Frío)

Cliente Objetivo: Empresas alimentarias y logísticas que requieren cámaras de refrigeración, congelación o túneles de choque llave en mano.

Alcance Incluido: Envolvente aislante, puertas, unidad condensadora/central, evaporador, tubería de cobre, cuadro eléctrico y puesta en marcha.

PAKET 04

Kit de Nave Frigorífica (Acero + Cerramiento + Cámaras + Puertas)

Cliente Objetivo: Inversores de exportación y proyectos regionales de almacenamiento en frío con equipos de montaje locales.

Alcance Incluido: Estructura metálica prefabricada (SerHangar), paneles de cubierta/fachada, paneles frigoríficos, puertas, accesorios y planos.

PAKET 05

Nave Frigorífica Llave en Mano (Edificio + Envolvente + Frío)

Cliente Objetivo: Inversores corporativos que desarrollan almacenes frigoríficos desde cero, plantas procesadoras o centros logísticos.

Alcance Incluido: Ingeniería completa, nave de acero, cerramiento, cámaras frigoríficas, puertas de muelle y frigoríficas, frío industrial y entrega.

Conceptos Ejemplo de Naves Frigoríficas (KS01 – KS04)

CAD SCHEMATIC 03 — COLD STORAGE BUILDING ARCHITECTURE

Two Structural Approaches: External Steel Frame vs. Box-in-Box Cold Rooms

With SerPan Cold + SerHangar integration, we engineer both standalone steel-framed cold storage buildings and T-bar suspended envelopes inside existing halls.

APPROACH A: STANDALONE STEEL-FRAMED COLD BUILDING THERMAL ENVELOPE (-22°C / +2°C) T-Bar Ceiling + Floor Insulation + Dock SerHangar Steel + External Roof/Facade + Cold Envelope APPROACH B: BOX-IN-BOX COLD ROOMS Room 1 (-18°C) Room 2 (+4°C) Self-Supporting Chambers Inside Existing Hall
BASE DE CONOCIMIENTO TÉCNICO (EK C)

Preguntas Frecuentes de Ingeniería y Suministro

Preguntas técnicas frecuentes sobre puertas frigoríficas, selección de espesor de panel, sellado térmico y proyectos llave en mano.

C31 What is the difference between building cold rooms inside an existing factory ("Box-in-Box") vs constructing a standalone cold storage building?

In a "Box-in-Box" project, the outer building already exists and insulated rooms are built inside. In a standalone "Cold Storage Building", SerPan Cold + SerHangar engineer the structural steel frame, external roof/facade cladding, internal insulated envelope, and loading docks as a single integrated facility.

C32 How are thermal bridges prevented in steel-framed cold storage buildings?

Primary steel columns and rafters are positioned outside the insulated thermal envelope wherever possible, with ceiling panels suspended via thermal-break hangers. Any internal columns are fully boxed with insulated panels and PU-injected joints.

C33 What is included in a Cold Storage Building Kit (B02)?

A pre-engineered package comprising structural steel members, external roof/facade cladding, internal cold room wall/ceiling panels, all insulated and traffic doors, flashing/corner profiles, suspension hardware, and assembly drawings—ideal for export and remote sites.

C34 Who handles civil works and concrete floor slabs in turnkey cold storage projects?

Foundations and civil concrete works are typically executed by the client's local civil contractor according to SerPan Cold load and elevation drawings, while floor vapor barriers, insulation, structural steel, panels, doors, and refrigeration are clearly defined in our Scope Matrix (EK H05).

C35 Why is the loading dock and sectional door interface critical for cold storage performance?

The truck dock interface is the most vulnerable link in the cold chain. Integrating insulated dock doors, inflatable/curtain dock shelters, and a conditioned staging corridor prevents ambient air infiltration during loading.

MESA DIRECTA DE INGENIERÍA Y OFERTAS

Seleccione su Vía de Presupuesto (4 Canales Técnicos)

Seleccione el flujo adecuado a su proyecto; sus medidas y criterios técnicos se enviarán directamente a nuestra Mesa de Ingeniería por WhatsApp. (+90 (505) 507 04 18)

MESA DE INGENIERÍA SERPAN COLD

Solicite Cotización Rápida para Puertas Frigoríficas, Paneles o Naves de Frío

Ya sea un pedido de puertas/paneles o una nave frigorífica llave en mano, envíenos sus medidas para recibir una oferta técnica desglosada en el mismo día.

Fabricación a Medida 60–200 mm PUR/PIR Estructura de Acero SerHangar Exportación a 32+ Países
Línea de Ingeniería WhatsApp