Every cold room door leaf and panel lot undergoes dimensional squareness checks, polyurethane density verification, gasket compression testing, and heater continuity inspection before crating.
Ficha Técnica Resumida
MANUFACTURING & QUALITYIntegrated Cold Chain Building, Panel & Door Systems
42 kg/m³ PUR / B-s1,d0 PIR sandwich panels, heavy-duty industrial cold storage doors, and central refrigeration packages manufactured at our Gebze plant.
42 kg/m³ PUR & B-s1,d0 PIR Cold Room Panels
Cam-lock or tongue-and-groove joints with 0.50 mm DX51D+Z pre-painted galvanized steel facings.
Industrial Sliding, Hinged & Monorail Doors
Heated frames, dual-row EPDM gaskets, and heavy-duty anodized aluminum tracks for -40°C blast and freezer rooms.
Steel-Framed Turnkey Cold Storage Buildings
187 m² to 1,000+ m² bolted structural steel frame, central refrigeration racks, and docked logistics facilities.
Marcas del Grupo CFY Ingeniería y Ecosistema de Fabricación Integrado
Operando bajo CFY Ingeniería desde 2007, nuestras marcas integran estructura metálica, paneles, puertas y perfiles bajo un mismo techo:
SerPan Cold
Centro especializado en puertas, paneles, cámaras frigoríficas y naves de almacenamiento en frío
SerPan Metal
Paneles sándwich de cubierta/fachada, chapas trapezoidales y envolvente industrial
SerHangar
Naves industriales de acero, hangares, fábricas y estructuras metálicas de gran luz
SerProfil
Perfiles estructurales de acero, correas C/Z y componentes de estructura metálica
CFY Mühendislik
Empresa matriz, diseño arquitectónico, ingeniería estructural y coordinación técnica
Preguntas Frecuentes de Ingeniería y Suministro
Preguntas técnicas frecuentes sobre puertas frigoríficas, selección de espesor de panel, sellado térmico y proyectos llave en mano.
C11 Which cold room panel thickness should be selected for each operating temperature regime?
General engineering guideline: 60–80 mm for +8/+15°C cool storage, 80–100 mm for +2/+8°C chillers, 100 mm for 0/+4°C fresh storage, 120–150 mm for -18/-22°C freezers, 150–180 mm for -25/-30°C deep freeze, and 180–200 mm for -35/-40°C blast freezers.
C12 What is the main difference between PUR and PIR insulated cold room panels?
Both provide high thermal insulation at 40–42 kg/m³ density, while PIR (Polyisocyanurate) features an enhanced isocyanurate ring structure that delivers superior fire resistance, reduced smoke emission, and compliance with industrial property insurance standards.
C13 What is the difference between Cam-Lock modular panels and continuous-line slip-joint panels?
Cam-lock modular panels allow rapid assembly and future disassembly/relocation for walk-in cold rooms. Continuous-line labyrinth slip-joint panels are engineered for tall industrial cold storage buildings and long partition walls up to 13.5 meters.
C14 Why is floor insulation critical in cold rooms and freezer chambers?
Without proper floor insulation in sub-zero rooms, ground moisture freezes and expands (frost heave), cracking the concrete slab. Modular rooms use birch-plywood + stainless steel floor panels, while forklift-rated warehouses use multi-layer high-compressive XPS/PIR below a reinforced concrete slab with underfloor heating or ventilation.
C15 Why are hygienic cove skirtings and rounded internal/external corner profiles (A02) required?
Sharp 90-degree wall-to-floor and wall-to-wall angles trap bacteria and organic residues. HACCP, IFS, and BRCGS food safety audits require coved (rounded radius) PVC/aluminium hygienic profiles for effortless sanitation.
C16 Which cold rooms require a pressure relief valve (A03)?
Rapid air contraction after door closure or defrost cycles creates strong vacuum pressure inside sealed rooms. Heated pressure relief valves are mandatory in all sub-zero freezers and blast rooms to prevent panel implosion and vacuum-locked doors.