MANUFACTURING & QUALITY SISTEMAS DE INGENIERÍA SERPAN COLD

Manufacturing, Quality Control & Shipment Preparation Standards

Every cold room door leaf and panel lot undergoes dimensional squareness checks, polyurethane density verification, gasket compression testing, and heater continuity inspection before crating.

+15°C → -40°C Chiller, Freezer & Blast Regimes
60 – 200 mm 40–42 kg/m³ PUR & PIR Core
EN 10346 & HACCP 9-Layer Hygienic Steel & Profiles
81 İl & 32+ Ülke Direct Dispatch from Gebze Hub
Manufacturing, Quality Control & Shipment Preparation Standards — SerPan Cold
MANUFACTURING & QUALITY: Manufacturing, Quality Control & Shipment Preparation Standards

Ficha Técnica Resumida

MANUFACTURING & QUALITY
Yalıtım Kalite Kontrolü
40–42 kg/m³ Homojen PUR / PIR Kapalı Hücre Oranı, Sac-Köpük Aderansı ve Gönye Hassasiyeti Testi
Kapı Fonksiyon Testi
Conta Baskı, Rezistans & Anti-Panik Sevkiyat Öncesi Her Kapıda Ohm Direnç ve Mekanik Açma/Kapama Testi
Yüzey & Hijyen Koruma
EN 10346 Sac & Koruyucu PE Film Montaj Sonuna Kadar Yüzeyi Çizilmeye Karşı Koruyan Fabrika Filmi
İhracat & Sevkiyat
Poz Numaralı Etiket & ISPM-15 Kasa Oda/Kapı Koduna Göre Numaralandırılmış Darbe Korumalı Paketleme

Integrated Cold Chain Building, Panel & Door Systems

42 kg/m³ PUR / B-s1,d0 PIR sandwich panels, heavy-duty industrial cold storage doors, and central refrigeration packages manufactured at our Gebze plant.

Marcas del Grupo CFY Ingeniería y Ecosistema de Fabricación Integrado

Operando bajo CFY Ingeniería desde 2007, nuestras marcas integran estructura metálica, paneles, puertas y perfiles bajo un mismo techo:

MARCA DEL GRUPO

SerPan Cold

Centro especializado en puertas, paneles, cámaras frigoríficas y naves de almacenamiento en frío

MARCA DEL GRUPO

SerPan Metal

Paneles sándwich de cubierta/fachada, chapas trapezoidales y envolvente industrial

MARCA DEL GRUPO

SerHangar

Naves industriales de acero, hangares, fábricas y estructuras metálicas de gran luz

MARCA DEL GRUPO

SerProfil

Perfiles estructurales de acero, correas C/Z y componentes de estructura metálica

MARCA DEL GRUPO

CFY Mühendislik

Empresa matriz, diseño arquitectónico, ingeniería estructural y coordinación técnica

BASE DE CONOCIMIENTO TÉCNICO (EK C)

Preguntas Frecuentes de Ingeniería y Suministro

Preguntas técnicas frecuentes sobre puertas frigoríficas, selección de espesor de panel, sellado térmico y proyectos llave en mano.

C11 Which cold room panel thickness should be selected for each operating temperature regime?

General engineering guideline: 60–80 mm for +8/+15°C cool storage, 80–100 mm for +2/+8°C chillers, 100 mm for 0/+4°C fresh storage, 120–150 mm for -18/-22°C freezers, 150–180 mm for -25/-30°C deep freeze, and 180–200 mm for -35/-40°C blast freezers.

C12 What is the main difference between PUR and PIR insulated cold room panels?

Both provide high thermal insulation at 40–42 kg/m³ density, while PIR (Polyisocyanurate) features an enhanced isocyanurate ring structure that delivers superior fire resistance, reduced smoke emission, and compliance with industrial property insurance standards.

C13 What is the difference between Cam-Lock modular panels and continuous-line slip-joint panels?

Cam-lock modular panels allow rapid assembly and future disassembly/relocation for walk-in cold rooms. Continuous-line labyrinth slip-joint panels are engineered for tall industrial cold storage buildings and long partition walls up to 13.5 meters.

C14 Why is floor insulation critical in cold rooms and freezer chambers?

Without proper floor insulation in sub-zero rooms, ground moisture freezes and expands (frost heave), cracking the concrete slab. Modular rooms use birch-plywood + stainless steel floor panels, while forklift-rated warehouses use multi-layer high-compressive XPS/PIR below a reinforced concrete slab with underfloor heating or ventilation.

C15 Why are hygienic cove skirtings and rounded internal/external corner profiles (A02) required?

Sharp 90-degree wall-to-floor and wall-to-wall angles trap bacteria and organic residues. HACCP, IFS, and BRCGS food safety audits require coved (rounded radius) PVC/aluminium hygienic profiles for effortless sanitation.

C16 Which cold rooms require a pressure relief valve (A03)?

Rapid air contraction after door closure or defrost cycles creates strong vacuum pressure inside sealed rooms. Heated pressure relief valves are mandatory in all sub-zero freezers and blast rooms to prevent panel implosion and vacuum-locked doors.

MESA DIRECTA DE INGENIERÍA Y OFERTAS

Seleccione su Vía de Presupuesto (4 Canales Técnicos)

Seleccione el flujo adecuado a su proyecto; sus medidas y criterios técnicos se enviarán directamente a nuestra Mesa de Ingeniería por WhatsApp. (+90 (505) 507 04 18)

MESA DE INGENIERÍA SERPAN COLD

Solicite Cotización Rápida para Puertas Frigoríficas, Paneles o Naves de Frío

Ya sea un pedido de puertas/paneles o una nave frigorífica llave en mano, envíenos sus medidas para recibir una oferta técnica desglosada en el mismo día.

Fabricación a Medida 60–200 mm PUR/PIR Estructura de Acero SerHangar Exportación a 32+ Países
Línea de Ingeniería WhatsApp