DOC10 • Konsept Rehber

DOC10 — Cold Storage Buildings & Steel-Framed Facility Concept Guide (KS01–KS04)

Architectural layouts, dock staging corridors, and structural system comparisons for 120 m², 500 m², 1,500 m², and 4,000 m² cold storage facilities.

DOC10 Konsept Rehber
Rev. v2.0 Technisches Datenblatt
DWG & PDF CAD- & Ausführungsdetails
B00 Zugehöriger Systemcode
DOC10 — Cold Storage Buildings & Steel-Framed Facility Concept Guide (KS01–KS04) — SerPan Cold
DOC10: Cold Storage Buildings & Steel-Framed Facility Concept Guide (KS01–KS04)
SERPAN COLD — CFY ENGINEERING TECHNISCHES DOKUMENTATIONSZENTRUM

Doc ID: DOC10 | Rev: v2.0 | Engineering GSM: +90 (505) 507 04 18

DOC10

Technische Spezifikations- und Prüftabelle

Konsept Kodu Tipik Taban Alanı ve Operasyonel Kurgusu
KS01 — Kompakt Soğuk Oda 80–150 m² | Mevcut bina içi +2/+8°C ve -18°C ikili oda + hazırlık alanı
KS02 — Bölgesel Dağıtım Deposu 400–600 m² | 3 soğuk oda + +8°C ön koridor (sas) + 2 yükleme kapısı
KS03 — Endüstriyel İşleme & Depo 1.200–1.800 m² | Üretim, şoklama (-35°C), donmuş muhafaza ve rampa koridoru
KS04 — Lojistik Soğuk Depo Binası 3.000–5.000 m² | Yüksek tavanlı çelik karkas, raf koridorları ve çoklu tır rampası

Weitere Technische Datenblätter & Checklisten (DOC01 – DOC16)

DOKUMENTIERTE SYSTEME

Zugehörige Produkte & Fertigungsdetails aus Unserem Werk

TECHNISCHE WISSENSDATENBANK (EK C)

Häufig gestellte Fragen zu Technik & Lieferung

Häufig gestellte technische Fragen zu Kühlraumtüren, Wahl der Paneelstärke, Dichtungsdetails und schlüsselfertigen Projektabläufen.

C01 What is the difference between "Clear Opening Size" and "Wall Cut-Out Size" when ordering a cold room door?

Clear opening size is the usable internal passage width and height when the door leaf is fully open (e.g., 1200×2100 mm for pallet jacks). Wall cut-out size is the structural opening cut into the panel or masonry wall to receive the door frame, typically +70/+80 mm wider and +40/+50 mm higher depending on the frame profile.

C02 Should I choose a hinged cold room door or a sliding cold room door?

For pedestrian or hand-trolley access up to 1100 mm clear width, a hinged cold room door (D01) is ideal. Whenever pallet jacks or forklifts operate, corridors are narrow, or clear width is 1200 mm and above, a sliding cold room door (D02) should be selected to eliminate leaf sag and save corridor swing space.

C03 Why is a frame heater cable mandatory on freezer (-18°C / -25°C) and blast freezer (-35°C / -40°C) doors?

In sub-zero rooms below 0°C, moisture condenses and freezes around the perimeter gasket. An integrated frame and threshold heater cable prevents the EPDM gasket from freezing onto the aluminium frame, avoiding gasket tearing and door jamming.

C04 How is internal emergency exit safety ensured on cold room doors?

All SerPan Cold hinged and sliding cold room doors feature a standard glow-in-the-dark internal safety release handle (anti-panic mechanism) that unlocks and opens the door from the inside with a single push, even if padlocked or key-locked from outside.

C05 Should I specify a flush threshold (thresholdless) or stepped threshold door?

For any doorway used by pallet jacks, wheeled trolleys, or forklifts, a flush floor (thresholdless) configuration with a drop-seal bottom gasket is mandatory. Stepped stainless steel thresholds are only used for pedestrian-only rooms where floor panels sit above an existing slab.

C06 What technical dimensions are required when ordering a monorail cold room door (D04)?

In addition to clear door width and height, we require the monorail track height from finished floor level, track profile type (tubular or flat/I-beam), centerline offset relative to the door opening, and top slot clearance dimensions.

DIREKTE INGENIEUR- & ANGEBOTSZENTRALE

Wählen Sie Ihren Anfragepfad (4 Technik-Kanäle)

Wählen Sie den passenden Anfragepfad; Ihre Maße und Parameter werden strukturiert direkt an unser WhatsApp-Ingenieurteam übermittelt. (+90 (505) 507 04 18)

SERPAN COLD INGENIEURBÜRO

Fordern Sie ein schnelles Angebot für Kühlraumtüren, Paneele oder Kühlhausbauten an

Ob einzelne Kühlraumtür, Paneellieferung oder schlüsselfertiges Stahl-Kühlhaus – senden Sie uns Ihre Maße für ein taggleiches technisches Angebot.

Sondermaßfertigung 60–200 mm PUR/PIR SerHangar Stahlbau-Integration Export in 32+ Länder
WhatsApp Technik-Beratung