FACILITY CONCEPT MODELS SERPAN COLD INGENIEURSYSTEME

Reference Facility Scenarios & Concept Layouts (KS01–KS04)

To help you benchmark your upcoming investment, explore our 4 reference cold storage facility concepts (120 m², 500 m², 1,500 m², and 4,000 m²) with complete door and panel schedules.

+15°C → -40°C Chiller, Freezer & Blast Regimes
60 – 200 mm 40–42 kg/m³ PUR & PIR Core
EN 10346 & HACCP 9-Layer Hygienic Steel & Profiles
81 İl & 32+ Ülke Direct Dispatch from Gebze Hub
Reference Facility Scenarios & Concept Layouts (KS01–KS04) — SerPan Cold
FACILITY CONCEPT MODELS: Reference Facility Scenarios & Concept Layouts (KS01–KS04)

Technische Kurzübersicht

FACILITY CONCEPT MODELS
KS01 (120 m²)
Bina içi +2°C Soğuk Oda + -18°C Donuk Oda + Hazırlık Alanı HORECA / Market / Küçük Üretim
KS02 (500 m²)
3 Bölmeli Bölgesel Dağıtım Deposu + +8°C Ön Koridor (Sas) + 2 Yükleme Kapısı
KS03 (1.500 m²)
Endüstriyel Gıda İşleme, -35°C Şoklama, -20°C Muhafaza ve Sevkiyat Rampası
KS04 (4.000 m²)
Yüksek Tavanlı Çelik Karkas 3PL Lojistik Soğuk Depo Binası + Çoklu Tır Rampası

5-Stufige Lieferpaket- & Leistungsumfang-Matrix (EK H05)

Wir definieren ab dem ersten Angebot transparent alle Arbeitspakete zwischen SerPan Cold und bauseitigen Leistungen:

PAKET 01

Nur Produktlieferung (Türen / Paneele / Zubehör)

Zielgruppe: Kälteanlagenbauer, Montagebetriebe, Händler und Unternehmen mit eigenem Montageteam.

Enthaltener Umfang: Maßgefertigte Kühlraumtüren, Isolierpaneele, Hygieneprofile, Beschläge und werkseitige Exportverpackung.

PAKET 02

Isolierte Raumhülle (Paneele + Türen + Vor-Ort-Montage)

Zielgruppe: Investoren, die Kälteaggregate separat beziehen, aber die Montage der Isolierhülle und Türen mit Herstellergarantie wünschen.

Enthaltener Umfang: Wand-, Decken- und Bodenpaneele, Kühlraumtüren, T-Deckenabhängung, Hygiene-Hohlkehlen und komplette Vor-Ort-Montage.

PAKET 03

Kompletter Kühlraum (Isolierhülle + Kälteanlage)

Zielgruppe: Lebensmittel- und Logistikbetriebe, die schlüsselfertige Kühl-, Tiefkühl- oder Schockräume in bestehende Gebäude einbauen.

Enthaltener Umfang: Isolierhülle, Türen, Verflüssigungssatz/Verbundanlage, Verdampfer, Kupferrohrnetz, Schaltschrank und Inbetriebnahme.

PAKET 04

Kühlhaus-Bausatz (Stahlbau + Außenhülle + Innenzellen + Türen)

Zielgruppe: Internationale Exportinvestoren und regionale Kühlhausprojekte mit lokalen Montageteams.

Enthaltener Umfang: Vorgefertigte Stahlkonstruktion (SerHangar), Dach-/Fassadenpaneele, Kühlraumpaneele, alle Türen, Zubehör und Montagepläne.

PAKET 05

Schlüsselfertiges Kühlhaus (Gebäude + Isolierhülle + Kältetechnik)

Zielgruppe: Unternehmensinvestoren, die neue Kühlhäuser, Fleisch-/Milchverarbeitungsbetriebe oder Logistikzentren errichten.

Enthaltener Umfang: Engineering, Stahlbauhalle, Außenverkleidung, Kühlzellen, Verlade- und Kühlraumtüren, Industriekälteanlage und Übergabe.

Beispiel-Kühlhauskonzepte (KS01 – KS04)

Marken der CFY Ingenieurgruppe & Integriertes Fertigungs-Ökosystem

Seit 2007 vereinen unsere Gruppenmarken Stahlbau, Paneele, Kühlraumtüren und Profile unter einem Dach:

GRUPPENMARKE

SerPan Cold

Fachzentrum für Kühlraumtüren, Paneele, Kühlraumsysteme und Kühlhausgebäude

GRUPPENMARKE

SerPan Metal

Dach-/Fassadensandwichpaneele, Trapezbleche und industrielle Gebäudehüllensysteme

GRUPPENMARKE

SerHangar

Industrielle Stahlhallen, Lagergebäude, Fabriken und weitgespannte Stahlbauten

GRUPPENMARKE

SerProfil

Stahlprofile, C/Z-Pfetten und Systemkomponenten für Stahltragwerke

GRUPPENMARKE

CFY Mühendislik

Unternehmensgruppe, Architekturplanung, Tragwerksplanung und technische Koordination

CAD SCHEMATIC 04 — FACILITY FLOW PLAN

Sample Cold Storage Facility Layout (Ante-Room Corridor + Multi-Chamber + Docks)

For energy efficiency and cold-chain integrity, all chilled and frozen chambers open into a conditioned (+8/+12°C) staging corridor rather than directly outdoors.

CHAMBER 01: FREEZER (-20°C) 150 mm PIR Panel + Sliding Door CHAMBER 02: CHILLER (+2°C) 100 mm PIR Panel + Sliding Door BLAST (-38°C) 200 mm Panel PLANT ROOM & OFFICE +8°C / +12°C CONDITIONED ANTE-ROOM CORRIDOR (SAS) — BOLLARD PROTECTED Sectional Dock Doors (D07) ↓          Dock Shelters ↓
TECHNISCHE WISSENSDATENBANK (EK C)

Häufig gestellte Fragen zu Technik & Lieferung

Häufig gestellte technische Fragen zu Kühlraumtüren, Wahl der Paneelstärke, Dichtungsdetails und schlüsselfertigen Projektabläufen.

C31 What is the difference between building cold rooms inside an existing factory ("Box-in-Box") vs constructing a standalone cold storage building?

In a "Box-in-Box" project, the outer building already exists and insulated rooms are built inside. In a standalone "Cold Storage Building", SerPan Cold + SerHangar engineer the structural steel frame, external roof/facade cladding, internal insulated envelope, and loading docks as a single integrated facility.

C32 How are thermal bridges prevented in steel-framed cold storage buildings?

Primary steel columns and rafters are positioned outside the insulated thermal envelope wherever possible, with ceiling panels suspended via thermal-break hangers. Any internal columns are fully boxed with insulated panels and PU-injected joints.

C33 What is included in a Cold Storage Building Kit (B02)?

A pre-engineered package comprising structural steel members, external roof/facade cladding, internal cold room wall/ceiling panels, all insulated and traffic doors, flashing/corner profiles, suspension hardware, and assembly drawings—ideal for export and remote sites.

C34 Who handles civil works and concrete floor slabs in turnkey cold storage projects?

Foundations and civil concrete works are typically executed by the client's local civil contractor according to SerPan Cold load and elevation drawings, while floor vapor barriers, insulation, structural steel, panels, doors, and refrigeration are clearly defined in our Scope Matrix (EK H05).

C35 Why is the loading dock and sectional door interface critical for cold storage performance?

The truck dock interface is the most vulnerable link in the cold chain. Integrating insulated dock doors, inflatable/curtain dock shelters, and a conditioned staging corridor prevents ambient air infiltration during loading.

DIREKTE INGENIEUR- & ANGEBOTSZENTRALE

Wählen Sie Ihren Anfragepfad (4 Technik-Kanäle)

Wählen Sie den passenden Anfragepfad; Ihre Maße und Parameter werden strukturiert direkt an unser WhatsApp-Ingenieurteam übermittelt. (+90 (505) 507 04 18)

SERPAN COLD INGENIEURBÜRO

Fordern Sie ein schnelles Angebot für Kühlraumtüren, Paneele oder Kühlhausbauten an

Ob einzelne Kühlraumtür, Paneellieferung oder schlüsselfertiges Stahl-Kühlhaus – senden Sie uns Ihre Maße für ein taggleiches technisches Angebot.

Sondermaßfertigung 60–200 mm PUR/PIR SerHangar Stahlbau-Integration Export in 32+ Länder
WhatsApp Technik-Beratung