120 MM PUR / PIR • U = 0.18 W/m²K

120 mm PUR / PIR Cold Room Panel: U-Value, Temperature Regime & Specifications

120 mm PUR/PIR cold room wall and ceiling panel (0.18 W/m²K) engineered for -18°C / -22°C Donmuş Muhafaza Odası with maximum span and compatible door selection.

120 mm 42 kg/m³ PUR / PIR
0.18 W/m²K Thermal U-Value
-18°C / -22°C Donmuş Muhafaza Odası Operating Regime
5.20 m Max Ceiling Span
120 mm PUR / PIR Cold Room Panel: U-Value, Temperature Regime & Specifications — SerPan Cold
PNL-120: 120 mm PUR/PIR (0.18 W/m²K)

بطاقة الملخص الهندسي السريع

PNL-120
Panel Thickness & Density
120 mm 40–42 kg/m³ Closed-Cell PUR / PIR
Thermal Transmittance (U-Value)
0.18 W/m²K
Recommended Temperature Regime
-18°C / -22°C Donmuş Muhafaza Odası
Max Self-Supporting Ceiling Span
5.20 m T-Bar Suspension A05 used above this span
Average Panel Weight
13.4 kg/m² 0.50 mm Dual-Side Pre-Painted Galvanized Steel
Compatible Cold Room Door
120 mm Kasa Rezistanslı Menteşeli (D01) veya Sürgülü (D02) Donuk Kapısı

Where Is the 120 mm Cold Room Panel Used?

With a thermal transmittance of 0.18 W/m²K, the 120 mm PUR/PIR cold room panel eliminates exterior surface condensation and minimizes compressor run-time in chambers operating at -18°C / -22°C Donmuş Muhafaza Odası.

When ceiling spans exceed 5.20 m, panels are suspended from overhead steel purlins using our thermal-break aluminum T-bar suspension system (A05).

Explore Other Panel Thicknesses (60 mm – 200 mm)

CAD SCHEMATIC 05 — PANEL JOINT & HYGIENIC COVE DETAIL

Deep Labyrinth / Cam-Lock Panel Joint & HACCP Rounded Cove Section

Thermal-break tongue-and-groove polyurethane joint geometry combined with R45 rounded PVC hygienic skirting that eliminates 90° bacterial traps.

1. LABYRINTH JOINT & CAM-LOCK DETAIL Cam-Lock + Dual Gasket Groove (40–42 kg/m³ PIR/PUR) 2. HACCP ROUNDED HYGIENIC COVE SKIRTING (A02) R45 Rounded PVC Cove Flexible Co-Extruded Lip Eliminates 90° Bacterial Traps
قاعدة المعرفة الهندسية (EK C)

الأسئلة الهندسية والتوريدية الشائعة

الأسئلة الفنية الأكثر شيوعاً حول أبواب الغرف الباردة، اختيار سماكة الألواح، تفاصيل الإحكام الحراري ومشاريع تسليم المفتاح.

C11 Which cold room panel thickness should be selected for each operating temperature regime?

General engineering guideline: 60–80 mm for +8/+15°C cool storage, 80–100 mm for +2/+8°C chillers, 100 mm for 0/+4°C fresh storage, 120–150 mm for -18/-22°C freezers, 150–180 mm for -25/-30°C deep freeze, and 180–200 mm for -35/-40°C blast freezers.

C12 What is the main difference between PUR and PIR insulated cold room panels?

Both provide high thermal insulation at 40–42 kg/m³ density, while PIR (Polyisocyanurate) features an enhanced isocyanurate ring structure that delivers superior fire resistance, reduced smoke emission, and compliance with industrial property insurance standards.

C13 What is the difference between Cam-Lock modular panels and continuous-line slip-joint panels?

Cam-lock modular panels allow rapid assembly and future disassembly/relocation for walk-in cold rooms. Continuous-line labyrinth slip-joint panels are engineered for tall industrial cold storage buildings and long partition walls up to 13.5 meters.

C14 Why is floor insulation critical in cold rooms and freezer chambers?

Without proper floor insulation in sub-zero rooms, ground moisture freezes and expands (frost heave), cracking the concrete slab. Modular rooms use birch-plywood + stainless steel floor panels, while forklift-rated warehouses use multi-layer high-compressive XPS/PIR below a reinforced concrete slab with underfloor heating or ventilation.

C15 Why are hygienic cove skirtings and rounded internal/external corner profiles (A02) required?

Sharp 90-degree wall-to-floor and wall-to-wall angles trap bacteria and organic residues. HACCP, IFS, and BRCGS food safety audits require coved (rounded radius) PVC/aluminium hygienic profiles for effortless sanitation.

C16 Which cold rooms require a pressure relief valve (A03)?

Rapid air contraction after door closure or defrost cycles creates strong vacuum pressure inside sealed rooms. Heated pressure relief valves are mandatory in all sub-zero freezers and blast rooms to prevent panel implosion and vacuum-locked doors.

مكتب الهندسة وعروض الأسعار المباشر

اختر مسار طلب عرض السعر (4 مسارات هندسية متخصصة)

اختر المسار المناسب لطلبك؛ سيتم تنسيق المقاسات والمعايير الفنية وإرسالها مباشرة إلى مكتبنا الهندسي عبر واتساب. (+90 (505) 507 04 18)

المكتب الهندسي لشركة SERPAN COLD

احصل على عرض سعر سريع لأبواب الغرف الباردة أو الألواح العازلة أو مباني التبريد

سواء كنت بحاجة إلى باب أو ألواح مفردة أو مستودع تبريد متكامل بهيكل فولاذي — أرسل مقاساتك ليقوم فريقنا الهندسي بإعداد عرض فني مفصل في نفس اليوم.

تصنيع بمقاسات خاصة ألواح 60–200 مم PUR/PIR تكامل الهياكل الفولاذية SerHangar تصدير إلى أكثر من 32 دولة
خط الهندسة عبر واتساب